Resultados no mundo real da lente intraocular TECNIS Eyhance

evidências de um estudo retrospectivo de grande volume na Argentina

Autores

  • Tomás Martín Castro Centro de Ojos Quilmes. Buenos Aires, Argentina
  • Luciano Perrone Centro de Ojos Quilmes. Buenos Aires, Argentina
  • Nazarena Nasif Centro de Ojos Quilmes. Buenos Aires, Argentina
  • Franco Perrone Centro de Ojos Quilmes. Buenos Aires, Argentina
  • Manuela Masseroni Centro de Ojos Quilmes. Buenos Aires, Argentina
  • José Russian Centro de Ojos Quilmes. Buenos Aires, Argentina
  • Diana Calero-Vera Centro de Ojos Quilmes. Buenos Aires, Argentina
  • Lucas Aguirre Centro de Ojos Quilmes. Buenos Aires, Argentina
  • Gerardo Valvecchia Centro de Ojos Quilmes. Buenos Aires, Argentina

DOI:

https://doi.org/10.70313/2718.7446.v18.n4.466

Palavras-chave:

cirurgia de catarata, Eyhance, lentes intraoculares, visão funcional

Resumo

Objetivo: Avaliar os resultados visuais e refrativos obtidos com uma lente intraocular em uma grande coorte não selecionada em um centro de cirurgia de catarata na Argentina.

Métodos: Estudo retrospectivo de casos consecutivos incluiu pacientes com implante da lente TECNIS Eyhance (ICB00) entre novembro de 2020 e novembro de 2024. A avaliação pós-operatória foi realizada um mês após a cirurgia. Foram registrados a acuidade visual à distância (AVD) pré-operatória com correção (c/c) e a acuidade visual sem correção (s/c) pós-operatória em escala logarítmica, a acuidade visual para perto sem correção (s/c) a 32 cm, o equivalente esférico manifesto (EE), o poder dióptrico implantado e a presença de complicações. A s/c foi medida utilizando a tabela de Jaeger até março de 2023 e, posteriormente, com uma tabela padronizada em escala logarítmica (Byromat); os valores de Jaeger foram convertidos para logMAR para análise.

Resultados: Foram incluídos 899 olhos de 518 pacientes. A potência dióptrica média implantada foi de 22,1 ± 2,5 D. O erro refrativo (ER) pré-operatório foi de +1,23 ± 2,3 D, diminuindo para -0,42 ± 0,50 D. A acuidade visual de perto (AVP) pré-operatória foi de 0,16 logMAR, melhorando para uma AVP sem visão (AVSC) de 0,04 logMAR. Nenhum olho apresentou perda de linhas de visão. A AVSC demonstrou desempenho funcional com valores predominantemente J1-J3 na fase inicial. Com a tabela logarítmica, a AVSC média foi de 0,26 ± 0,11 logMAR (principalmente entre 0,2 e 0,3 logMAR).

Conclusão: A lente Eyhance proporcionou resultados confiáveis ​​para acuidade visual de longe e de perto sem correção, com um perfil de segurança favorável ao longo de quatro anos.

Downloads

Os dados de download ainda não estão disponíveis.

Referências

1. Fernández J, Rocha-de-Lossada C, Zamorano-Martín F, Rodríguez-Calvo-de-Mora M, Rodríguez-Vallejo M. Positioning of enhanced monofocal intraocular lenses between conventional monofocal and extended depth of focus lenses: a scoping review. BMC Ophthalmol 2023; 23(1): 101. doi:10.1186/s12886-023-02844-1.

2. Li J, Sun B, Zhang Y et al. Comparative efficacy and safety of all kinds of intraocular lenses in presbyopia-correcting cataract surgery: a systematic review and meta-analysis. BMC Ophthalmol 2024; 24(1): 172. doi:10.1186/s12886-024-03446-1.

3. Nagyova D, Tappeiner C, Blaha A, Goldblum D, Kyroudis D. Visual outcomes and patient satisfaction with extended monovision-an innovative strategy to achieve spectacle independence in refractive lens exchange. J Clin Med 2025; 14(16): 5684. doi: 10.3390/jcm14165684.

4. Srinivasan S, Nyankerh C, Hull J, Suryakumar R. Meta-analysis of defocus curves of monofocal, enhanced monofocal and extended depth of focus IOLs. BMJ Open Ophthalmol 2025; 10(1): e002025. doi:10.1136/bmjophth-2024-002025.

5. Bianchi GR. Lentes intraoculares de profundidad de foco extendida (EDOF): revisión narrativa. Oftalmol Clin Exp 2025; 18(3): e277-e286. doi: https://doi.org/10.70313/2718.7446.v18.n3.447.

6. Jeon YJ, Yoon Y, Kim TI, Koh K. Comparison between an intraocular lens with extended depth of focus (Tecnis Symfony ZXR00) and a new monofocal intraocular lens with enhanced intermediate vision (Tecnis Eyhance ICB00). Asia Pac J Ophthalmol (Phila) 2021; 10(6): 542-547. doi:10.1097/APO.0000000000000439.

7. Gigon E, Bouthour W, Panos GD, Pajic B, Massa H. Real world outcomes of the new Tecnis Eyhance IOL. Eur J Ophthalmol 2023; 33(3): 1390-1397. doi:10.1177/11206721221146675.

8. Singh G, Sidhharthan KS, Reddy JK, Sundaram V, Thulasidas M. Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses. Indian J Ophthalmol 2024; 72(2): 181-184. doi:10.4103/IJO.IJO_681_23.

9. Negishi K, Masui S, Ayaki M, Torii H, Yotsukura E, Nishi Y. Clinical results and factors affecting visual function in eyes implanted with an enhanced monofocal intraocular lens. Clin Ophthalmol 2023; 17: 3965-3973. doi:10.2147/OPTH.S438599.

10. Janekova A, Polachova M, Piñero DP, Studeny P. Comparison of visual acuity and optical quality between higher-order aspheric monofocal and standard introcular lenses. Int J Ophthalmol 2025; 18(4): 598-605. doi:10.18240/ijo.2025.04.05.

11. Corbett D, Black D, Roberts TV et al. Quality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular Lens. Eye (Lond) 2024; 38(Suppl 1): 9-14. doi:10.1038/s41433-024-03039-8.

12. Alfonso-Bartolozzi B, Martínez-Alberquilla I, Fernández-Vega-Cueto L et al. Optical and visual outcomes of a new refractive extended depth of focus intraocular lens. J Refract Surg 2025; 41(4): e333-e341. doi:10.3928/1081597X-20250221-02.

13. Niknahad A, Wu Z, Son HS, Auffarth GU, Khoramnia R, Łabuz G. Evaluation of Clareon Vivity and PureSee intraocular lenses: optical quality, depth of focus and misalignment effects. Sci Rep 2025; 15(1): 26943. doi:10.1038/s41598-025-07970-y.

14. Son HS, Łabuz G, Wu Z et al. Optical differentiation of presbyopia-correcting intraocular lenses with improved intermediate vision from a single manufacturer. J Refract Surg 2025; 41(10): e1098-e1105. doi:10.3928/1081597X-20250805-05.

Publicado

2025-12-22

Edição

Secção

Artigos Originais

Como Citar

1.
Castro TM, Perrone L, Nasif N, et al. Resultados no mundo real da lente intraocular TECNIS Eyhance: evidências de um estudo retrospectivo de grande volume na Argentina. Oftalmol. Clín. Exp. 2025;18(4):e467-e480. doi:10.70313/2718.7446.v18.n4.466

Artigos Similares

1-10 de 359

Também poderá iniciar uma pesquisa avançada de similaridade para este artigo.

Artigos mais lidos do(s) mesmo(s) autor(es)