Ahmed valve dislocation secondary to contusion

Authors

  • Fernando Godin Grupo de Investigación y Salud Ocular, Departmento de Oftalmología, Universidad El Bosque, Unbosque, Bogotá D.C., Colombia
  • María A Piedrahita Escuela de Medicina, Universidad CES, Medellín, Colombia
  • Catalina Betancur Escuela de Medicina, Universidad CES, Medellín, Colombia
  • María A. Orrego Escuela de Medicina, Universidad CES, Medellín, Colombia

DOI:

https://doi.org/10.70313/2718.7446.v15.n04.202

Keywords:

Ahmed valve dislocation

Abstract

We present a 40-year-old man, who presented at a tertiary care unit with a history of blunt trauma to the right eye (RE) three years ago in a football game with a ball. He developed post-traumatic uveitis with an acute increase in IOP. He required surgical management with an AGV. He presents persistent pain and foreign body sensation in his RE after trauma from falling from a bicycle a month ago. Slit-lamp examination showed dislocation of the temporal-superior AGV with a conjunctival cyst, discoric pupil secondary to pulling due to the valve at the 9-10 meridian. IOP was within limits in both eyes; Fundus examination was adequate.

References

Kang YK, Shin JP, Kim DW. Long-term surgical outcomes of Ahmed valve implantation in refractory glaucoma according to the type of glaucoma. BMC Ophthalmol 2022; 22: 270.

Gross LG, Lemos RD, Almeida VD et al. Spontaneous extrusion of the Ahmed valve: a case report. eOftalmo 2021; 7. Available: http://eoftalmo1.hospedagemdesites.ws/details/204/en-US

Riva I, Roberti G, Oddone F et al. Ahmed glaucoma valve implant: surgical technique and complications. Clin Ophthalmol 2017; 11: 357-367.

Moreno-Montañés J, Velázquez-Villoria A, Sabater AL, Salinas-Alamán A. Intraocular lens dislocation and tube shunt in the posterior chamber: a case report. BMC Ophthalmol 2015; 15: 63.

Lee CK, Ma KT, Hong YJ, Kim CY. Long-term clinical outcomes of Ahmed valve implantation in patients with refractory glaucoma. PloS One 2017; 12: e0187533.

Al-Shahwan S. Transcorneal tube erosion of an ahmed valve implant in an adult. Middle East Afr J Ophthalmol 2010; 377-378.

Mansoori T. Recurrent scleral patch graft shrinkage and Ahmed valve tube exposure. Nepal J Ophthalmol 2019; 11: 232-236.

Kumar S, Ichhpujani P, Thakur S, Singh RB. Traumatic corneal perforation with exteriorisation of Ahmed glaucoma valve tube. BMJ Case Rep 2018; 2018: bcr2018225181.

Downloads

Published

2022-12-28

How to Cite

[1]
Godin, F., Piedrahita, M.A., Betancur, C. and Orrego, M.A. 2022. Ahmed valve dislocation secondary to contusion. Oftalmología Clínica y Experimental. 15, 4 (Dec. 2022). DOI:https://doi.org/10.70313/2718.7446.v15.n04.202.

Issue

Section

Imágenes Científicas